QINGDAO G&Z TRADING CO., LTD.
Brown Red Chlorinated Rubber Coating

Brown Red Chlorinated Rubber Coating

Send Inquiry

The offered Brown Red Chlorinated Rubber Coat has been formulated by blending raw material like aliphatic polyurethane resin, function materials, acrylic acid resin, epoxy resin and modifier to name a few. Generally, this coating material is used for coating of swimming pool floor. Its high chlorine content has made it non flammable by nature. Apart from that, the application of this coating can be noticed in road, bridge and various plants. Exceptional chemical resistance capacity, outstanding weather protection capacity, long lasting coating quality, environment friendly content and water proof formation are some of its distinctive characteristics. With firm commitment to quality, we have emerged as a successful manufacturer, supplier and exporter of premium grade Brown Red Chlorinated Rubber Coat.
Features

  • The offered coating material is the perfect blending of raw materials like acrylic acid resin and aliphatic polyurethane resin
  • Unique aging resistance capacity
  • It does not turn into yellowish color even after long period of its application
  • Good heat insulation capacity
  • Outstanding sunlight reflection ability

RESISTANCE GUIDE

HEAT RESISTANCE

It can prevent up to 120℃ dry heat

WEATHERABILITY

It maintains shine or brightness of applied surface even after exposing to harsh weather.

SOLVENTS

Useful for preventing splash of mineral oil and aliphatic solvent 

ACIDS

Ideal choice for checking spillage of most of the acids.

ALKALIS

Ability to prevent spillage and sprinkling of different types of alkalis. 

SALTS

Good protection capacity against alkali salts and neutral salts 

WATER

Exceptional resistance properties against saline and fresh water. It is not ideal for absorption. 


USES: This coating is utilized for coating all sorts of pressure containers like  external surface of the steel structure workshop, oil tanker, PLG spherical tank, refrigerated trucks and warehouse structure. This coating acts as a reliable heat and cooling insulation medium.

TYPICAL PROPERTIES AND APPLICATION DATA

Primer(glue)

Intermediate(glue) Topcoat(glue)

COLOR B

Brown Red Light Grey /White White

DENSITY

1.4g/cm3

1.4g/cm3

1.2g/cm3

SOLIDS BY VOLUME

56%

56%

42%

SOLIDS BY WEIGHT

76%

76%

72%

SPREADING RATE

5.0 m2/kg(80um DFT)

5.0 m2/kg(80um DFT)

6.7 m2/kg(50um DFT)

DRYING TIME(23℃)

Touch 4 Hr Handle 24 Hr

OVERCOAT INTERVAL(23℃)

Min 8 Hr Max 7 Days

STORAGE

at least 12 months (dry, cool and under cover )

PACKAGING

Primer Part A: 21kg Part B: 3kg

Intermediate

Part A: 21kg Part B: 3kg

Topcoat Part A

20kg Part B: 4kg


DIRECTIONS Primer(glue), Intermediate(glue), Topcoat(glue) is a two pack, before using stir or using dynamic mixer mixing two components completely, then add part B to part A, and fully stir, life for 4 hours. Rate of cure will vary depending on temperature and other factors such as ventilation, film thickness, humidity, thinner. The temperature of stir will >15℃, otherwise thinner should be added for needed viscosity after stir. Overmuch thinner will lead sag and slow cure rate, thin film, thinner should be added after mixed. Practical spreading rates may be reduced 5%—25% for wastage of different application conditions.

APPLICATION

STEEL: The surface coated by primer or intermediate paint should be dry and clean, no oil and other pollutants. When overcoat on a two-component film such as epoxy paint, wharf's pavement quality for old film should be taken if more than the longest accordance with time.
Don’t apply at temperatures below 5℃ or above 40℃. Don’t apply at relative
humidity above 85% or when the surface is less than 3℃ above the dew point. Don’t apply if there is fog, rain, snow or strong wind.
BRUSH/ROLLER: Suitable for small areas only. Apply even coats of the mixed material to the prepared surface. Thin if necessary with up to 0-15% with Special Thinner(Primer, Intermediate X-2, Topcoat X-5). Additional coats may be required to attain specified thickness.
CONVENTIONAL SPRAY: Thinning is not normally required, however 0-15% of Special Thinner(Primer, Intermediate X-2, Topcoat X-5) can be added.
AIRLESS SPRAY: Thinning is not normally required, however 0-5% of Special Thinner(Primer, Intermediate X-2, Topcoat X-5) can be added. Pump ratio is 23:1 or 32:1 and fluid tip is 0.33-0.38mm.
Overcoating: Aged coating should be tested for lifting by a method such as ‘X’cut or crosshatch methods. If it lifts, remove it. The surface must be free of oil, grease and other contaminants.
CLEAN UP: Special Thinner (Primer, Intermediate X-2, Topcoat X-5)

SAFETY: Pay attention to the safety precautions before and after using this product. Users should comply with the provision of the respective country or local government. It’s dangerous or deadly to eating it. To avoid inhalation of thinner steams and spray mists.
Use protective wears correctly; the skin and eyes should avoid contacting it. Use with good ventilation. This product is flammable. All sources of ignition must be eliminated in, or near the working area. DO NOT SMOKE. Fight fire with foam, CO2 or dry chemical powder. On burning will emit toxic fumes.

Notes: The data in the manual is get from standard experiments and may be vary from different conditions in use. Please refer to the latest manual if the data is altered and we would not inform specially.